AE SERIES Liquid Oxygen Pump Breathing Apparatus

AE SERIES Liquid Oxygen Pump Liquid Oxygen Pump Liquid Pump Breathing Apparatus

Oxygen filling pump: AE SERIES Liquid Oxygen Pump Liquid Oxygen Pump Liquid Pump Breathing Apparatus
The gas booster pump is mainly used for filling oxygen respirator and compressed oxygen self - rescuer.It is filled with oxygen or other non-combustible gas in a large storage cylinder into another cylinder.Automatic control of filling pressure.
Oxygen filling pump action: oxygen filling pump is specially for small - pressure oxygen tanks filling oxygen equipment.The oxygen is lifted from the gas cylinder and filled to a small volume of oxygen cylinder to achieve the desired pressure value, and is also suitable for the filling of non-combustible gases such as nitrogen and carbon dioxide.

AE SERIES Liquid Oxygen Pump Liquid Oxygen Pump Liquid Pump Breathing Apparatus

Application AE SERIES Liquid Oxygen Pump Liquid Oxygen Pump Liquid Pump Breathing Apparatus
Widely used in medical, fire, aviation, petrochemical, metallurgy, ships and other use of gas.
AE SERIES Liquid Oxygen Pump Liquid Oxygen Pump Liquid Pump Breathing Apparatus
Operating procedures: AE SERIES Liquid Oxygen Pump Liquid Oxygen Pump Liquid Pump Breathing Apparatus
1, oxygen filling pump should choose to work in the room with a clean without dust, use the site shall not be lower than 0 ℃ temperature.
2. The filling pump can be bolted to the horizontal pedestal and can be placed on the horizontal base.Between the filling pump and the base between the thick rubber plate with vibration reduction, contact with the base should be stable.
3. It is strictly prohibited to contact the parts of any fatty object with the lubricating liquid of water _ glycerin.
4. Before the first use, the mechanical oil should be injected into the body, and after each change of the mechanical oil, the oil must be wiped clean.No oil is allowed to leak out from the joint of the upper and lower body, the sealing ring and the sealing cover.
5. Smoking should be strictly prohibited in the place of use.Backpackers must wear clean clothes without grease and wash hands with soap before working.
6. All the tools used must be cleaned and removed, and then cleaned thoroughly with cotton yarn.
7. The motor wiring must be good, and the network should be equipped with fuse and ground wire.Indoor lighting should be equipped with explosion-proof lampshade.
8. All parts that are in contact with oxygen and water, lubricating liquid, should be cleaned regularly and cleaned with compressed oxygen before filling.The cleaning materials include ether, alcohol, carbon tetrachloride, and aviation gasoline.
9. The oxygen filling workers must regularly check the safety performance of the oxygen quality, gas and oxygen cylinder in the gas cylinder.There should be reliable safety isolation facilities between the storage place and the inflatable place.
10. The oxygen cylinder must be subjected to a pressure test every 3 years.After the new purchase or water pressure test, the oxygen cylinder should be diluted 2 to 3 times before filling.
11. The oxygen cylinder should be handled gently, and the distance between the warm air and the high temperature should be more than 2 meters.
12. The work of oxygen filling must be carried out by professional trained personnel, and non-professional personnel are not allowed to operate the oxygen-filled operation without authorization.
13. Before filling the pump, carefully check whether the parts are clean and reliable.The abd-200 and af-101 oxygen filling pumps should fill the piping system with oxygen from 18 to 22 mpa.The AF-102 oxygen filling pump should be filled with oxygen of 30~32 mpa, and check whether air leakage is detected everywhere with soapy water.If any adverse phenomena are found, try to eliminate them in time so as not to reduce the inflating efficiency or risk.
14. Check whether the rotation direction of the crankshaft is consistent with the direction of the arrow on the belt cover.
Check the check valve.First start the motor, closed set switch for inflatable (1) ABD - 200 type, AE101 type oxygen filling pump, can observe the middle pressure gauge change: if two suction valve tightness, whose hands stationary;If there is an air tight, the needle does not jump.If one or two exhaust valves are not tight, the gauge needle rises and is in tune with the plunger movement.

Dongda Group has 10 series, more than 70 products. Including mines lifting equipment, transport equipment, communication signal equipment, personal-protective equipment, ventilation equipment, mining cleaning equipment, supporting equipment, drilling machines and accessories, mining pump, electrical equipment, lighting equipment ,rock drilling equipment and other products.coal feeder ,air cannon ,gas detector,
Now ,hundreds kinds of products have been exported to more than 60 Countries and regions. Such as USA, Australia, Russia, Canada, Middle East, Africa etc
Dongda Group has succeeded in passing a number of certification systems which are ISO9001, 2008 quality management system certification, CE certification ,Alibaba GIS certification, SGS certification (made in China) . With excellent quality and competitive price , Dongda group is to establish long-term, broader economic and trade cooperation and strategic partnership with a number of large state-owned enterprises and customers, and won the unanimous approval of them.

AE SERIES Liquid Oxygen Pump Liquid Oxygen Pump Liquid Pump Breathing Apparatus

Oxygen Filling Pump (6)

Oxygen Filling Pump (7)

Oxygen Filling Pump (1)





Contact us if you need more details on AE SERIES Liquid Oxygen Pump. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Liquid Oxygen Pump、Liquid Pump Breathing Apparatus. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Production Rescuer Equipment > Oxygen Filling Pump